LPW-80A Cemented carbide tooth drop hammer fatigue impact testing machine
Function and characteristics
The LPW-80A Cemented carbide tooth drop hammer fatigue impact testing machine is suitable for testing the cemented carbide teeth used in engineering machinery special equipment. It can be used for multiple impact tests. It is used to evaluate the simulated use conditions of such products, and to test the durability and safety of the products. At the same time, it is also possible to conduct impact comparison tests on cemented carbide samples of the same material, different specifications and forms to identify the quality of the cemented carbide products.
The test machine adopts PLC program control technology, which can adjust the impact height and wide range. The swing arm drives the wire rope to automatically lift the hammer to the predetermined height. The machine has good reliability and high precision, and meets the requirements of the professional standard ZBN72026-90 drop hammer impact tester technical condition standard.
Main technical parameters
1, The use temperature: 10-35 °C
2, In an environment where there is no vibration or strong electromagnetic field interference;
3, There is no corrosive medium in the environment, and pay attention to the ventilation of the electric control box.
4, Power supply: AC 220V ± 10% 2A
5, Hammer mass accuracy: 4.5±0.06Kg (cemented carbide teeth can be installed)
6, The maximum impact height: 0.2-1.8M
7, Height positioning error: less than ± 10mm
8, Dimensions: about 3100 * 1800 * 2600mm (L*W*H)