JWJ-10 Electronic Metal Materials Repeated Bending Testing Machine
  • JWJ-10 Electronic Metal Materials Repeated Bending Testing Machine

JWJ-10 Electronic Metal Materials Repeated Bending Testing Machine

This tester is mainly used for metal wire rod repeated bending test, to test metal wire rod bearing of plastic deformation performance and the defects in the repeated bending test

Main usage and range of application

This tester is mainly used for metal wire rod repeated bending test, to test metal wire rod bearing

of plastic deformation performance and the defects in the repeated bending test. Equipped with

plank clamping device, which can also make test on plank sample.

This machine is widely used in steel, construction industry, and steel wire, wire and cable and

other production manufacturers.

It is suitable for φ3-φ10 metal wire, equipped with special toolings, which still can do other standard

metal bending test.

 

Main technology parameters

1 Sample diameter                      Φ3-φ10mm

2 Sample length                          150-200mm

3 Bending angle Degree             ±90°

4 Bending speed time /minute     ≤60

5 Numeration range time              0-99999

6 Motor power                              1.5  Kw 

7 External dimensions                  740*520*1200mm

8 Tester weight                           about 220kg

 

Working conditions

1. Room-temperature 10-35°c

2. In the stable basis, level to relocate.

3. In no vibration circumstances

4. No corrosive substance around

5. No apparent electromagnetic interference

6. Power supply voltage fluctuation range does not exceed the rated voltage 380V plus or minus 10;

7. Tester surrounding should have some spare space.